Multipoint 1 1Installation and User InstructionsPOWER PACKPlease read and understand these instructions before starting work. Please leave th
107.0 FAULT FINDINGYOUR MAREY POWER PACK SHOULD GIVE TROUBLE FREE OPERATION, HOWEVER SHOULD A FAULT OCCUR THE TABLE BELOW SHOULD AL-LOW MOST FAULTS TO
Multipoint 11 11The following comprehensive list of spare parts is available for your Santon Power Pack. Please refer to the rating label on
12P.O. Box 6281Delbrey # 211San Juan, P.R. 00912Tel: (787) 727-0277Fax: (787) 727-1810www.marey.comSpares StockistsThe Seller will make good by repair
2INTRODUCTIONThank you for purchasing a Santon Power Pack. The Power Pack unvented pressure system water heater is manufactured to the highest standar
Multipoint 3 3MATERIALS Back plate, cover - ABS Element(s) - Copper sheathed rod type.DIMENSIONS Height - 210mm Width - 160mm Depth - 10
4IMPORTANT INFORMATION2.1 Products designed by Santon are to British and European and UL Standards. These appliances are safe and without risk, p
Multipoint 5 5WATER REQUIREMENTS3.1 The heater must be connected via the pressure relief valve to a cold supply having a minimum pressur
6ELECTRICAL REQUIREMENTS3.6 This appliance must be earthed.3.7 The installation must comply with national/local code of practices and Electricity
Multipoint 7 7PREPARATION4.1 Remove the xing screw which holds the front cover onto the back plate of the Power Pack heater. Carefully r
85.0 COMMISSIONED5.1 Once installed, the heater will operate automatically when the outlet valve is opened. The valve must be opened fully to obta
Multipoint 9 96.0 MULTIPLE INSTALLATIONS6.1 When larger volumes of water are required than can be provided by one heater, multiple install